Air Conditioner Voltage Protector AVS30 guard 220V 9830 is able to automatically detect the mains voltage, and if the voltage is outside a preset acceptable range, it will shut down the connected device (such as the air conditioner) to protect the device from voltage fluctuations.
Model No. | 9830 |
Brand Name | YXST |
Operating Voltage |
220VAC |
Operating Frequency |
50 Hz-60 Hz |
Over Voltage Cut-off |
230V~ 300adjustable |
Under Voltage Cut-off |
150V~ 230V adjustable |
Delay Time for Reconnection | 0s~10mins adjustable |
Output Capacity |
30 Amps , 6600 Watts |
Connect By | Direct Wiring |
Standard Package |
Double Blister + Card or Color Box |
Warranty | 1 Year |
Voltage protector for 220V air conditioner AVS30 9830 usually needs to be directly connected to the power line, so you need to pay attention to the wiring requirements and safety specifications of the appliance during installation. It is best to have a professional electrician perform the installation to ensure compliance with safety standards.
Through the built-in AVS (Automatic Voltage Stabilization) technology, the power supply is automatically cut off when the voltage exceeds the preset range, and reconnected after the voltage returns to normal, avoiding damage to the equipment due to overvoltage or undervoltage, and effectively suppressing the impact of instantaneous high voltage on precision electrical appliances such as televisions and computers.
1. Standard voltage
- Household air conditioners: usually use 220V single-phase AC (frequency 50Hz), suitable for ordinary split air conditioners of 1-3 horsepower.
- Central air conditioners/commercial air conditioners: Some high-power models (such as 5 horsepower and above) need to use 380V three-phase AC to meet higher power requirements.
2. Safe voltage range
- Fixed frequency air conditioners: The normal working voltage range is 187V-242V. If it is lower than 187V, the compressor may not start, and if it is higher than 242V, the circuit may be damaged.
- Variable frequency air conditioners: The adaptability range is wider, generally 198V-242V, and the operating stability in a low-voltage environment is better than that of fixed frequency air conditioners.
3. Hazards of abnormal voltage
- Voltage is too low (<187V): The compressor is difficult to start, the operating current increases, and the motor may overheat or burn.
- Voltage is too high (>242V): It may break down the circuit board or capacitor, shortening the life of the equipment.
Number of horses |
Applicable area(㎡) | Cooling power(W) | Heating power(W) |
---|---|---|---|
1 horse | 10-15 | 650-750 | 1000-1200 |
1.5 horse | 20-25 | 900-1100 | 1500-1800 |
2 horse | 30-35 | 1100-1300 | 2000-2500 |
3 horse | 40-50 | 1300-1500 | 3000-3500 |
>> What is a single phase automatic voltage switcher (AVS)
>> (Automatic Voltage Switch)AVS Protector: Ensuring Safety and Efficiency
>> Why AVS Voltage Protector is the best guardian for your electronic devices?